Lose one control plane, then two

The cluster runs three control planes and three etcd members. With one gone, etcd keeps quorum and nothing changes. With two gone, etcd stops, the API goes with it and the workloads keep serving. This drill shows both.

I ran it twice on 16 November 2026. The first run ended early, for a reason that had nothing to do with etcd. The second run is the one that counts.

Everything runs on my home server, in two terminals.

Before I start

  • just cluster-check passes.

  • just drill-watch runs in the first terminal. I wait for Start the drill before I break anything, because it deploys echo first.

  • The steps run in the second terminal.

  • Both terminals append to one log, so neither overwrites the other:

    just drill-watch 2>&1 | tee -ai drill.log    # first terminal
    just cluster-check 2>&1 | tee -a drill.log   # every check below
    

    -i keeps tee alive through Ctrl-C, so the summary lands too. cluster-check prints its failures to stderr, hence 2>&1.

drill-watch prints a line whenever something changes: which control planes are up, which one holds the VIP and whether echo, a read, a cached read and a write succeed. deploy/README.md explains each probe.

Steps

1. Lose one control plane

multipass stop --force cp-2

--force pulls the power. A clean shutdown would let etcd hand over leadership politely, and real failures don’t.

Two of three members is still a majority, so etcd keeps writing. If cp-2 held the VIP, kube-vip on another control plane takes it once the 15 s Lease runs out. Every probe stays ok, apart from a gap while the VIP moves.

2. Check it

After a minute, so the node controller has noticed:

just cluster-check

It fails, and should: kube-vip isn’t ready on cp-2, four of five nodes are Ready and two of three etcd members are healthy. The API still answers on the VIP.

3. Lose a second

multipass stop --force cp-3

One of three is not a majority. etcd can’t elect a leader, so it refuses writes and consistent reads. cp-1’s API server stops being ready, but it still answers reads at resourceVersion=0 from its watch cache.

kube-vip renews its Lease through that API, every 2 s, and stands down if it can’t renew for 10 s. So the VIP disappears, and the cached reads go with it. The API doesn’t stay read-only. It goes away.

echo keeps answering. The Pods run on the workers, and kube-proxy’s iptables rules stay in the kernel. Nothing on the data path needs the control plane until something changes.

4. Check it

just cluster-check

It stops before it reaches the API:

no control plane's API server is ready (running: cp-1): kubeadm init hasn't run, or etcd has lost quorum

It only asks running VMs. The first run shows why that matters.

5. Bring both back

multipass start cp-2 cp-3

Once a second member is up, etcd has a majority again and elects a leader. The API comes back, kube-vip takes its Lease and the VIP returns. The drill-watch lines go back to ok.

6. Prove it

Ctrl-C in the first terminal prints how many probes of each kind passed. Then:

just cluster-check

Cilium on the two rebooted nodes takes a minute to be ready, so the first check may fail on it alone.

What I saw

First run, 16 November 2026

Stage one went as expected: cp-2 stopped and the cluster carried on without it.

Stage two lasted about a minute. cp-3 went at 19:53:13. 32 s later, the API dropped drill-watch’s connection, and from 19:53:50 the VIP didn’t answer at all:

E1116 19:53:50.592902 ... dial tcp 10.97.0.250:6443: connect: no route to host

That’s kube-vip standing down, as step 3 predicts. Then I ran just cluster-check, and afterwards all five VMs were running. I hadn’t started any of them. Multipass’s log, trimmed:

Nov 16 19:53:13 multipassd: started: qemu-img snapshot -l .../instances/cp-3/...
Nov 16 19:54:00 multipassd: started: qemu-system-x86_64 ... .../instances/cp-2/...
Nov 16 19:54:20 multipassd: started: qemu-system-x86_64 ... .../instances/cp-3/...

cluster-check looked for a ready API server by running multipass exec on each control plane in turn. cp-1 wasn’t ready, because etcd had no quorum, so it moved on to cp-2 and cp-3. multipass exec starts a stopped instance and retries. Its help doesn’t say so, but exec.cpp does. The check booted cp-2, waited 20 s for it, then booted cp-3. The tool meant to report the outage ended it.

drill-watch never reached its loop. It was still waiting for echo to roll out when I stopped cp-3, and it timed out once the API went.

Both scripts now only touch running VMs, and drill-watch reads the VIP holder from multipass list. It also says when to start.

Second run, 16 November 2026

With both fixes in:

20:16:10  +   1s  up cp-1,cp-2,cp-3  vip cp-1  echo ok  read ok  cache ok  write ok
20:16:20  +  11s  up cp-1,cp-3  vip cp-1  echo ok  read ok  cache ok  write ok
20:16:58  +  49s  up cp-1  vip cp-1  echo ok  read fail  cache ok  write fail
20:17:20  +  71s  up cp-1  vip none  echo ok  read fail  cache fail  write fail
20:19:46  + 217s  up cp-1,cp-2,cp-3  vip none  echo ok  read fail  cache fail  write fail

Losing cp-2 changed nothing. cp-1 held the VIP, so there was nothing to move.

Losing cp-3 stopped consistent reads and writes on the next probe. The API server kept serving cached reads for another 22 s, until kube-vip stood down and the VIP went. echo didn’t notice.

cluster-check stopped early and left cp-2 and cp-3 stopped:

no control plane's API server is ready (running: cp-1): kubeadm init hasn't run, or etcd has lost quorum

Both were back by 20:19:46. I stopped drill-watch before quorum returned:

echo: 79 of 79 passed
read: 29 of 79 passed
cache: 35 of 79 passed
write: 29 of 79 passed

echo answered every probe. Cached reads outlived consistent ones by six probes. With probes timing out, a round took about 3 s, not 1.

Then cluster-check:

API on 10.97.0.250: ok, held by cp-1
kube-vip: running on 3 control planes, all reading admin.conf
nodes: 5 of 5 Ready
etcd: 3 of 3 members healthy
cilium: ready on 3 of 5 nodes

etcd, the API and kube-vip were back. Cilium on cp-2 and cp-3 was still starting. Once it was ready:

API on 10.97.0.250: ok, held by cp-1
kube-vip: running on 3 control planes, all reading admin.conf
nodes: 5 of 5 Ready
etcd: 3 of 3 members healthy
cilium: ready on 5 nodes

The check after stage one is missing. drill-watch wrote through tee -i without -a, so it wrote over what the check had appended.

What else the drill found

echo is meant to keep one Pod on each worker, so losing either leaves one serving. Two checks after the drill showed its spread rule didn’t hold that.

A lost worker’s Pod couldn’t be replaced. I cordoned edge-1 and deleted its echo Pod. The replacement sat in Pending:

0/5 nodes are available: 1 node(s) didn't match pod topology spread constraints, 1 node(s) were unschedulable, 3 node(s) had untolerated taint(s).

The rule allows at most one Pod more on any node than on the emptiest. By default it counts every node, tainted ones included, so cordoned edge-1 and the three control planes each counted as holding none. A second Pod on data-1 broke the rule. A dead worker is tainted the same way. nodeTaintsPolicy: Honor leaves tainted nodes out of the count.

A rollout put both Pods on one worker. Applying that fix rolled echo out again, and both new Pods landed on data-1 (columns trimmed):

NAME                    READY   STATUS        RESTARTS   AGE   IP             NODE
echo-5976856569-r52d5   1/1     Terminating   0          18m   10.244.3.87    edge-1
echo-7bbd856f5b-ddzh8   1/1     Running       0          16s   10.244.5.176   data-1
echo-7bbd856f5b-v7z4q   1/1     Running       0          4s    10.244.5.2     data-1

The rule counts every Pod labelled app=echo, old ones included. A rollout replaces them one at a time, so at each step the old Pods still running made data-1 look no fuller than edge-1. matchLabelKeys: [pod-template-hash] counts only Pods from the same rollout.

The rule now reads:

topologySpreadConstraints:
  - maxSkew: 1                         # at most one Pod more than the emptiest node
    topologyKey: kubernetes.io/hostname
    whenUnsatisfiable: DoNotSchedule
    nodeTaintsPolicy: Honor            # cordoned, dead and control-plane nodes don't count
    matchLabelKeys:
      - pod-template-hash              # only this rollout's Pods count
    labelSelector:
      matchLabels:
        app: echo

With both in place, a rollout left one Pod on each worker, and the same cordon put the replacement on data-1 straight away:

NAME                    READY   STATUS    RESTARTS   AGE   IP             NODE
echo-5cb4c8bc96-5brtt   1/1     Running   0          52s   10.244.5.133   data-1
echo-5cb4c8bc96-vblxj   1/1     Running   0          22s   10.244.5.18    data-1

The scheduler never moves a running Pod, so after the uncordon both stayed on data-1. kubectl -n drill rollout restart deployment/echo spreads them again.

Neither causes trouble while every node is healthy, which is why a drill is the place to find them.

Why three or five

etcd writes only when a majority of members agree. Quorum is ⌊n/2⌋ + 1.

MembersQuorumCan lose
110
220
321
431
532

Even sizes buy nothing. Four members survive one loss, like three, but give one more machine to fail, and every write waits for three acknowledgements instead of two. Two is worse than one, because losing either stops writes.

Partitions decide it. Four members can split two and two, and then neither side has a majority and the cluster stops. Split three or five in two and one side always keeps a majority. The majority rule itself is what stops a split brain: two halves can’t both accept writes, because only one of them can be a majority.

When it goes wrong

A control plane won’t rejoin etcd

--force is a power cut. etcd syncs every commit to disk, but a cut mid-write can leave its log or database torn. On restart, etcd-cp-N crashes in a loop and the kubelet keeps restarting it.

I remove the member and join the node again. That only works for cp-2 and cp-3: after a reset, cluster-up would run kubeadm init on cp-1 and build a new, empty cluster. If cp-1 is the broken one, I join it by hand with step 5 of the bootstrap runbook.

From a healthy control plane, I find the member’s ID with member list and remove it with member remove, using the flags in bootstrap.md. Then:

kubectl delete node cp-N
multipass exec cp-N -- sudo kubeadm reset -f
just cluster-up

cluster-up treats a control plane as joined once its Node is labelled, so the Node has to go before it will join cp-N again.

A node comes back on a new address

Each etcd member’s peer URL and certificate name the node’s IP. A new address means the others can’t reach it, or won’t trust it. Multipass never expires a lease, so it shouldn’t happen here, but on real hardware it’s the classic case. The fix is the same: remove, reset and join.

The VIP doesn’t come back

kube-vip needs a working API to take its Lease, so the VIP returns after quorum, not before. If etcd is healthy and the VIP is still missing, I read kube-vip’s log on a control plane:

multipass exec cp-1 -- sudo crictl logs --tail 50 \
  $(multipass exec cp-1 -- sudo crictl ps -a -q --latest --name kube-vip)

What I don’t do

With two members down, etcd --force-new-cluster on the survivor gets writes going again. The other two then come back with history the new cluster doesn’t share, and both have to be wiped and joined again. It’s for members that are never coming back, not ones that are slow.